Kabanova E.V., Baloshin Yu.A., Popov I.Yu., Dudin M.G. Modeling of resonance effects in spine with additional fixing elements. Scientific and Technical Journal of Information Technologies, Mechanics and Optics, 2019, vol. 19, no. 6, pp. 1115–1121 (in Russian). doi: 10.17586/2226-1494-2019-19-6-1115-1121


Abstract
Subject of Research. We study the procedure of natural frequencies calculation for a system consisting of a human spine with fixing elements. Resonant effects can occur in the vicinity of such system leading to stability violation or structure destruction. Method. A mathematical model of the conditional vertebral column is proposed, consisting of two anatomically-physiologically isolated columns: the spinal cord (dorsal longitudinal column) and its musculoskeletal “case” (ventral longitudinal column). The model includes complementary boundary condition — an additional fixing element. To solve this problem, the vertebral complex is modeled using a geometric graph. A fourth-order differential operator on the edges of a geometric graph is considered. The graph is a model of a biomechanical system — the spine and metal structure. It is assumed that there are point potentials at the vertices of the graph that model the bond character between the graph elements. A system of differential equations with boundary conditions (conditions for matching solutions on adjacent edges) is solved to find the spectrum of the operator dangerous for the integrity of the mechanical frequency system. Main Results. A technique is proposed for detection of biomechanical system eigenfrequencies that lead to resonant effects. A correct model of a metric graph is created with a fourth-order operator on the edges and the conditions of point interaction at the vertices. Frequency values are obtained for specific values of the system parameters. Practical Relevance. The described method for detection of hazardous frequencies can be used in the treatment of patients with scoliosis to prevent breakage of the installed metal structure and save the patient’s life.

Keywords: metric graph, fourth-order operator, point potential, operator spectrum, scoliosis, biomechanical system

Acknowledgements. This work was partially supported by the Government of the Russian Federation (grant 08-08) and grant 16-11-10330 of the Russian Science Foundation.

References
  1. Szendroi M., Sim F.H. Color atlas of clinical orthopedics. Springer Science & Business Media, 2009, 480 p.
  2. Sampiev M.T., Laka A.A. Scoliosis. Moscow, GEOTAR-Media Publ., 2008, 156 p. (in Russian)
  3. Pokornyi Yu.V., Penkin O.M., Priadiev V.L., Borovskikh A.V.,  Lazarev K.P., Shabrov S.A. Differential equations on geometric graphs. Moscow, FIZMATLIT Publ., 2005, 272 p. (in Russian)
  4. Borovskikh A.V., Mustafokulov R., Lazarev K.P. Pokornyi Yu.V. A class of fourth-order differential equations on spatial networks. Doklady Akademii nauk, 1995, vol. 345, no.6, pp. 730–732. (in Russian)
  5. Kiik J.C., Kurasov P., Usman M. On vertex conditions for elastic systems. Physics Letters, Section A: General, Atomic and Solid State Physics, 2015, vol. 379, no. 34-35, pp. 1871–1876. doi: 10.1016/j.physleta.2015.05.017
  6. Dudin M., Mikhailovsky M., Sadovoy M., Pinchuk D., Fomichev N. Idiopathic scoliosis: who is to blame and what to do?. Journal of Spine Surgery, 2014, no. 2, pp. 8–20. (in Russian)
  7. Popov I., Lisitsa N., Baloshin Y., Dudin M., Bober S. Variational model of scoliosis.Theoretical and Applied Mechanics, 2018, vol. 45, no. 2, pp. 167–175. doi: 10.2298/TAM170818012P
  8. Scoliosis X-ray stock photo. Image of cauda, health, chiropractic – 21752394. Available at:https://www.dreamstime.com/stock-images-scoliosis-ray-image21752394 (accessed: 28.06.2019).
  9. Popov A.I., Popov I.Y., Baloshin Y.A., Kobylenko D.M., Dudin M.G. Modeling of vertebral system by the nudged elastic band method. AIP Conference Proceedings, 2018, vol. 1978, pp. 140010. doi: 10.1063/1.5043790
  10. Maurel N., Lavaste F., Skalli W. A three-dimensional parameterized finite element model of the lower cervical spine: study of the influence of the posterior articular facets. Journal of Biomechanics, 1997, vol. 30, no. 9, pp. 921–93Копировать1. doi: 10.1016/S0021-9290(97)00056-0
  11. Greaves C.Y., Gadala M.S., Oxland T.R. A three-dimensional finite element model of the cervical spine with spinal cord: an investigation of three injury mechanisms. Annals of Biomedical Engineering, 2008, vol. 36, no. 3, pp. 396–405. doi: 10.1007/s10439-008-9440-0
  12. Lafage V., Dubousset J., Lavaste F., Skalli W. 3D finite element simulation of cotrel - dubousset correction. Computer Aided Surgery, 2004, vol. 9, no. 42006, pp. 17–25. doi: 10.3109/10929080400006390
  13. Dudgen E., Stratton E., Bowden A., Howell L. Spinal implant development, modeling, and testing to achieve customizable and nonlinear stiffness. Journal of Medical Devices, Transactions of the ASME, 2012, vol. 6, no. 2, pp. 021010. doi: 10.1115/1.4006543
  14. Ledoux Y., Ramos A., Mesnard M. Optimizing the architecture of a dynamic spinal implant for customized mechanical behavior. Procedia CIRP, 2017, vol. 65, pp. 273–278. doi: 10.1016/j.procir.2017.04.056
  15. Monède-Hocquard L., Mesnard M., Ramos A., Gille O. Selection of polymer material in the design optimization of a new dynamic spinal implant. Advances in Biomechanics and Applications, 2015, vol. 2, no. 1, pp. 41–52.


Creative Commons License

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License
Copyright 2001-2024 ©
Scientific and Technical Journal
of Information Technologies, Mechanics and Optics.
All rights reserved.

Яндекс.Метрика